Filters
Question type

Study Flashcards

Explain the benefits of the new generator-ready loadcenters.

Correct Answer

verifed

verified

These new loadcenters are only slightly ...

View Answer

The most important installation practice for a permanently installed swimming pool is the proper grounding and bonding together of all ____________________ parts in and around the pool.

Correct Answer

verifed

verified

Pool motors can be cord-and-plug connected but if they are, the cord can't be more than __________ feet long and must contain an equipment-grounding conductor sized according to Table 250.122.


A) 1
B) 2
C) 3
D) 4

E) A) and D)
F) A) and B)

Correct Answer

verifed

verified

The conductors that provide electrical power to permanently installed pool lighting fixtures must be GFCI protected if the voltage is above __________ .


A) the low-voltage contact limit
B) 24 volts
C) 120 volts
D) the high-voltage contact limit

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

Article __________ in the NEC covers the requirements for swimming pools, hot tubs, and hydromassage tubs.


A) 110
B) 250
C) 440
D) 680

E) All of the above
F) B) and D)

Correct Answer

verifed

verified

Outdoor lighting fixtures can be mounted on trees.

A) True
B) False

Correct Answer

verifed

verified

A permanently installed swimming pool must have at least one 125-volt, 15- or 20-ampere receptacle located a minimum of __________ feet from the inside wall of the pool.


A) 3
B) 5
C) 6
D) 10

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Section 625.40 requires any receptacle outlet that is installed in a garage for the purpose of charging an electric vehicle to be supplied by a separate branch circuit and the branch circuit cannot have any other outlets on it.

A) True
B) False

Correct Answer

verifed

verified

Incandescent lamps used for lighting in a garage can be replaced with LED lamps.

A) True
B) False

Correct Answer

verifed

verified

The NEC requires that if a feeder supplying a detached garage from the service in the main house has an equipment-grounding conductor installed with the feeder, the grounded conductor __________ be connected to the equipment-grounding conductor or to the grounding electrode system in the garage.


A) may
B) shall
C) shall not
D) could

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

When installing branch-circuit wiring in a raceway from an electrical panel inside the house to pool-associated motors, an insulated equipment grounding conductor __________.


A) must be installed
B) may be installed
C) shall not be installed
D) depends if the raceway is metallic or nonmetallic

E) B) and C)
F) A) and C)

Correct Answer

verifed

verified

For spas and hot tubs, at least one 125-volt, 15- or 20-ampere rated receptacle must be installed at least __________ from the inside wall of the spa or hot tub.


A) 3
B) 5
C) 6
D) 10

E) A) and C)
F) B) and D)

Correct Answer

verifed

verified

A(n) ____________________ is a rotating machine used to convert mechanical energy into electrical energy.

Correct Answer

verifed

verified

If the feeder supplying power to a loadcenter in a detached garage is installed with an equipment grounding conductor, the NEC does not require a separate grounding electrode system to be established at the detached garage.

A) True
B) False

Correct Answer

verifed

verified

In attached garages, the NEC requires at least __________.


A) one single 125-volt receptacle only
B) one duplex 125-volt receptacle only
C) one wall switch-controlled lighting outlet only
D) one 125-volt, 15- or 20-ampere receptacle for each vehicle bay and one wall switch-controlled lighting outlet

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

All 15- and 20-ampere, 125- and 250-volt nonlocking receptacles used outdoors must be listed as weather-resistant.

A) True
B) False

Correct Answer

verifed

verified

PVC conduit is not permitted as the only means of support for a junction box used with underwater lighting when wiring permanently installed swimming pools.

A) True
B) False

Correct Answer

verifed

verified

A GFCI feed-through receptacle is an acceptable means to provide the required GFCI protection to hydromassage bathtubs and their associated equipment.

A) True
B) False

Correct Answer

verifed

verified

For a permanently installed swimming pool, any 15- or 20-ampere, 125 through 250 volt rated receptacle located within __________ feet of a pool's inside wall must be GFCI protected.


A) 3
B) 10
C) 12
D) 20

E) A) and D)
F) All of the above

Correct Answer

verifed

verified

If a lighting fixture is installed under a canopy or under an open porch, it is considered to be in a(n) ____________________ location.

Correct Answer

verifed

verified

Showing 21 - 40 of 49

Related Exams

Show Answer